venturi3d¶
英語 | 日本語
Venturi tube -- axisymmetric converging-throat-diverging duct, the classic obstruction flow meter. Single-phase D3Q19, ISO C++ stdpar. Validates two textbook results at once: (1) the axial static-pressure signature -- a drop at the throat that RECOVERS in the diffuser, matched against the Bernoulli + continuity prediction; and (2) the venturi DISCHARGE COEFFICIENT Cd, the ratio of the true volumetric flow to the ideal flow the measured throat pressure drop would imply.
概要: ベンチュリ管の流量係数。Bernoulli と Borda-Carnot による理論値と比較する。
Geometry¶

Animation¶
Fields¶
この計算が最後の出力ステップで書き出した場をそのまま描いたもの。3D ケースは中央断面。


Build & run¶
venturi3d [Rin] [Rthroat] [Re] [steps] [umean] [axial_csv] [field_csv]
このページの図を作った計算のコスト(Miyabi-G Grace CPU (72 cores, -stdpar=multicore)): 46.1 s wall。
Validation¶
| Tier | T2 — 単点比較 |
| QoI | discharge_coefficient |
| Reference | Bernoulli + Borda-Carnot; ISO 5167 discharge coefficient |
| Gate | — ゲートなし |
Source & run details¶
| Item | Value |
|---|---|
| Target | orheo-venturi3d |
| Source | native/benchmarks/venturi3d.cpp |
| Lattice | D3Q19 |
| GPU twin | no |
| Modules | lbm_d3q19.hpp |
| Gallery run | 2026-07-27 @ 7628c0cf |
| Args | `` |
| Wall time | 46.10 s |
| CPU time | 1628.78 s |
| Device | Miyabi-G Grace CPU (72 cores, -stdpar=multicore) |
Computation log¶
この計算の実際の出力(先頭と末尾)。
=== venturi3d D3Q19 -- converging-throat-diverging duct ===
grid 140x40x40 (0.22 Mcell) axis (19.5,19.5)
Rin=18.0 Rthroat=11.0 beta=d_t/d_in=0.611 area ratio A_in/A_t=2.678
sections: bore[0,20) cone[20,40) throat[40,50) diffuser[50,110) bore[110,140)
u_in=0.0400 (peak throat Mach~0.186) Re_Din=200.0 nu=0.00720 tau=0.52160
solid cells=115276 fluid cells=108724 A_inlet=1020 A_throat=384 (ratio 2.656)
step 0/40000 throat: u_bulk=0.0369 Q=14.19 dQ=1.42e+01 p_c=0.33333
step 2000/40000 throat: u_bulk=0.0898 Q=34.48 dQ=2.03e+01 p_c=0.32601
step 4000/40000 throat: u_bulk=0.1063 Q=40.83 dQ=6.35e+00 p_c=0.32557
step 6000/40000 throat: u_bulk=0.1126 Q=43.24 dQ=2.41e+00 p_c=0.32832
step 8000/40000 throat: u_bulk=0.1129 Q=43.35 dQ=1.09e-01 p_c=0.33103
step 10000/40000 throat: u_bulk=0.1107 Q=42.51 dQ=8.40e-01 p_c=0.33258
step 12000/40000 throat: u_bulk=0.1085 Q=41.68 dQ=8.29e-01 p_c=0.33300
step 14000/40000 throat: u_bulk=0.1073 Q=41.21 dQ=4.69e-01 p_c=0.33281
...
axis u1=0.0440 ut=0.1356
(1b) bulk/tap static drop dp_meas=0.008800 dp_Bernoulli(bulk)=0.004718 (86.5%)
[bulk over-predicts dp: peaked laminar profile carries extra KE]
inlet u1=0.0395 throat ut=0.1049 (=u1*A_in/A_t=0.1049)
(2) diffuser recovery (p_out-p_th)/(p_in-p_th) = 0.168 (1=lossless; mean p)
(3) discharge coeff Cd = Q_actual/Q_ideal = 0.7331
Re_throat = ut*Dt/nu = 320 (venturi Cd is Re-dependent; ISO 0.98
is the Re>2e5 asymptote -- lower at this laminar Re)
caveats: staircased bore (few-% area error) + weak LBM compressibility (Mach)