1D arterial model (Model H) — lumped-parameter formulas¶
English | Japanese
What the model does¶
For 1 segment of the aorta, it computes the pulse pressure (systolic and diastolic pressure), wave speed, Womersley number and Reynolds number directly from formulas, given mean blood pressure, heart rate and cardiac output (arterial.hpp, orheo-1d model=arterial). Despite the name "1D", it has neither time stepping nor an axial grid. It is not a model that solves partial differential equations for area and flow rate, or a network of branches. It is meant for getting a rough idea of the conditions before a 3D computation.

- 3-element Windkessel (Westerhof 1971): Z_in(ω) = Zc + Rp / (1 + iωRpC)
- Wave speed (Moens–Korteweg): c = √(Eh / 2ρR), characteristic impedance Zc = ρc/A
- Rp and C are determined from the mean pressure, mean flow rate and decay time constant (default 1.79 s)
- The flow waveform is approximated by the mean plus 1 harmonic. Pulse pressure = 2 q₁ |Z_in(ω)|
The defaults are a human ascending aorta (R = 12.5 mm, L = 0.20 m, heart rate 70/min, cardiac output 5.0 L/min, mean pressure 93 mmHg).

Tests (test_arterial.cpp)¶
Comparisons with exact limits (matches the Poiseuille resistance as ω → 0, Z_in → Zc at high frequency, E × 4 gives c × 2, etc.) and checks that values fall within textbook ranges (Womersley number 12–25, wave speed 3–8 m/s, systolic 95–145, diastolic 55–95, pulse pressure 25–60 mmHg). The output with the default values is Womersley number 18.6, wave speed 4.26 m/s, 110/76 mmHg (pulse pressure 34 mmHg), mean Re 1285 and maximum 3672 (from the description of commit 93b102b).
There is no validation against measured or published waveforms. The pulse pressure is described as "indicative only (±25 % against measured waveforms)", and there is no test supporting this ±25 % either.
Handing over to a 3D computation¶
It cannot answer local quantities such as wall shear stress or OSI, so a 3D computation is always recommended (orheo-womersley-pipe3d in Womersley pulsatile pipe). The grid guideline R/dx = 5.7 α (with the defaults R ≥ 106 cells, about 6.0 × 10⁷ cells in total) was taken from the Womersley pulsatile pipe sweep.
Open points¶
- "Model H" is also attached to the series-duct model (duct_system.hpp), so the name clashes.
- No source is given for the decay time constant 1.79 s or for the ranges used in the tests.